Pacing Clin Electrophysiol ; 44(4): 651-656, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33592679

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) with autonomic modulation may be more successful than PVI alone for atrial fibrillation (AF) ablation and may be signaled by changes in sinus rhythm heart rate (HR) post ablation. We sought to determine if a change in sinus rhythm HR predicted AF recurrence post PVI. METHODS: Patients who underwent AF ablation from 2000 to 2011 were included if sinus rhythm was noted on ECG within 90 days pre and 7 days post ablation. Basic ECG interval and HR changes were analyzed and outcomes determined. RESULTS: A total of 1152 patients were identified (74.3% male, mean age 57 ± 11 years). Mean AF duration was 5.2 ± 5.3 years. Paroxysmal AF was noted in 712 (61.8%) of the patients. Mean EF was 61% ± 6%. Sinus rhythm HR was 61 ± 11 pre-ablation and 76 ± 13 bpm post-ablation (27% ± 24% increase, p < .001). The ability of relative HR change post-ablation to predict AF recurrence was borderline (hazard ratio 0.65 [0.41-1.01], p = .067). With patients separated into quartiles based on the relative HR change, the upper quartile with the largest relative increase in HR had a significantly lower rate of AF recurrence compared to the lowest quartile following multi variable modeling (p = .038). There were significant changes in PR (171 ± 28 to 167 ± 30 ms) and QTc (424 ± 25 to 434 ± 29 ms) intervals (both p < .001) but these were not predictive of outcome. CONCLUSION: Relative changes in HR post AF ablation correlates with AF recurrence. Further prospective studies are needed to confirm this relationship.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Frequência Cardíaca/fisiologia , Veias Pulmonares/cirurgia , Adulto , Fibrilação Atrial/fisiopatologia , Criança , Feminino , Átrios do Coração/fisiopatologia , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Recidiva
2.
J Cardiovasc Electrophysiol ; 32(4): 1053-1061, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33566447

RESUMO

BACKGROUND: Effective therapy for inappropriate sinus tachycardia (IST) remains challenging with high rates of treatment failure and symptom recurrence. It is uncertain how effective pharmacotherapy and procedural therapy are long-term, with poor response to medical therapy in general. METHODS: We retrospectively reviewed all patients with the diagnosis of IST at a tertiary academic medical center from 1998 to 2018. We extracted data related to prescribing patterns and symptom response to medical therapy and sinus node modification (SNM), assessing efficacy and periprocedural complication rates. RESULTS: A total of 305 patients with a formal diagnosis of IST were identified, with 259 (84.9%) receiving at least one prescription medication related to the condition. Beta-blockers were the most commonly used medication (n = 245), with a majority of patients reporting no change or worsening of symptoms, and poor response was seen to other medication classes. Improvement was seen significantly more often with ivabradine than beta blockers, though the sample size was limited (p = .003). Fifty-five patients (18.0% of all IST patients), mean age 32.0 ± 9.1 years, underwent a SNM procedure, with an average of 1.8 ± 0.9 procedures per patient. Acute symptomatic improvement (<6 months) was seen in 58.2% of patients. Long-term complete resolution of symptoms was seen in 5.5% of patients, modest improvement in 29.1%, and no long-term benefit was seen in 65.5% of patients. CONCLUSIONS: Among all medical therapies, there were high rates of treatment failure or symptom worsening in over three-quarters of patients in our study. Ivabradine was most beneficial, though the sample size was small. While most patients receiving SNM ablation for IST perceive an acute symptomatic improvement, almost two-thirds of patients have no long-term improvement, and resolution of symptoms is quite rare. AV node ablation with pacemaker implantation following lack of response to SNM offered increased success, though the sample size was limited.


Assuntos
Ablação por Cateter , Taquicardia Sinusal , Adulto , Ablação por Cateter/efeitos adversos , Humanos , Ivabradina , Estudos Retrospectivos , Nó Sinoatrial , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/tratamento farmacológico , Taquicardia Sinusal/cirurgia , Resultado do Tratamento , Adulto Jovem
3.
Circ Arrhythm Electrophysiol ; 13(4): e008239, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32186936

RESUMO

Left bundle branch block may be due to conduction system degeneration or a reflection of myocardial pathology. Left bundle branch block may also develop following aortic valve disease or cardiac procedures. Patients with heart failure with reduced ejection fraction and left bundle branch block may respond positively to cardiac resynchronization therapy. Lead placement via the coronary sinus is the mainstay approach of cardiac resynchronization therapy. However, other options, including physiological pacing, are being explored. In this review, we summarize the salient pathophysiologic and clinical aspects of left bundle branch block, as well as current and future strategies for management.


Assuntos
Fascículo Atrioventricular/fisiopatologia , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Frequência Cardíaca , Potenciais de Ação , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Humanos , Recuperação de Função Fisiológica , Fatores de Risco , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 31(1): 137-143, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31749258

RESUMO

BACKGROUND: Limited data are available regarding the demographics, disease associations, and long-term prognosis of patients with inappropriate sinus tachycardia (IST). OBJECTIVE: To establish epidemiologic data for patients with IST, including symptom onset, comorbid disease, and long-term outcomes. METHODS: We retrospectively reviewed all patients with an IST diagnosis at the Mayo Clinic (Rochester, MN) during a 20-year period (1998-2018). We extracted demographic data and clinical outcomes compared to an age and gender-matched control group with atrioventricular nodal reentry tachycardia (AVNRT). RESULTS: Within the study period, a total of 305 patients with IST were identified (mean follow-up 3.5 years) with 92.1% female and mean age 33.2 ± 11.2 years. The most frequently identified circumstances triggering the condition included pregnancy (7.9%) and infectious illness (5.9%) while the most common comorbid conditions were depression (25.6%) and anxiety (24.6%). At diagnosis, the mean left ventricular ejection fraction (LVEF) was 62.3 ± 6.2%, with 77 patients having follow-up echocardiographic data. No significant difference in LVEF was seen after a mean 4.9 ± 4.3-year follow-up (baseline LVEF 59.8 ± 10.7% vs subsequent 61.4 ± 8.1%; P = .2971). Two deaths occurred within the study period, with one related to myocardial infarction and the other noncardiac; compared to an age and gender-matched AVNRT control group there was no excess mortality during the follow-up period. CONCLUSIONS: In our study cohort, IST predominately affects young females with structurally normal hearts and modest coexistent psychiatric disease. In most cases of IST, a major event occurring just before or at the time of diagnosis could not be identified, although nearly 8% of patients first noted symptoms during or shortly after pregnancy. In our cohort, there was no evidence of cardiomyopathy or mortality related to IST.


Assuntos
Frequência Cardíaca , Síndrome da Taquicardia Postural Ortostática/epidemiologia , Síndrome da Taquicardia Postural Ortostática/terapia , Taquicardia Sinusal/epidemiologia , Taquicardia Sinusal/terapia , Potenciais de Ação , Adulto , Comorbidade , Feminino , Humanos , Masculino , Minnesota/epidemiologia , Síndrome da Taquicardia Postural Ortostática/diagnóstico , Síndrome da Taquicardia Postural Ortostática/fisiopatologia , Gravidez , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Adulto Jovem
7.
Pacing Clin Electrophysiol ; 42(9): 1236-1242, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31355952

RESUMO

BACKGROUND: Recipients of implantable cardioverter defibrillator (ICD) generator replacement with multiple medical comorbidities may be at higher risk of adverse outcomes that attenuate the benefit of ICD replacement. The aim of this investigation was to study the association between the Charlson comorbidity index (CCI) and outcomes after ICD generator replacement. METHODS: All patients undergoing first ICD generator replacement at Mayo Clinic, Rochester and Beth Israel Deaconess Medical Center, Boston between 2001 and 2011 were identified. Outcomes included: (a) all-cause mortality, (b) appropriate ICD therapy, and (c) death prior to appropriate therapy. Multivariable Cox regression analysis was performed to assess association between CCI and outcomes. RESULTS: We identified 1421 patients with mean age of 69.6 ± 12.1 years, 81% male and median (range) CCI of 3 (0-18). During a mean follow-up of 3.9 ± 3 years, 52% of patients died, 30.6% experienced an appropriate therapy, and 23.6% died without experiencing an appropriate therapy. In multivariable analysis, higher CCI score was associated with increased all-cause mortality (Hazard ratio, HR 1.10 [1.06-1.13] per 1 point increase in CCI, P < .001), death without prior appropriate therapy (HR 1.11 [1.07-1.15], P < .0001), but not associated with appropriate therapy (HR 1.01 [0.97-1.05], P = .53). Patients with CCI ≥5 had an annual risk of death of 12.2% compared to 8.7% annual rate of appropriate therapy. CONCLUSIONS: CCI is predictive of mortality following ICD generator replacement. The benefit of ICD replacement in patients with CCI score ≥5 should be investigated in prospective studies.


Assuntos
Efeitos Psicossociais da Doença , Desfibriladores Implantáveis , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Retratamento , Estudos Retrospectivos , Resultado do Tratamento
9.
Indian Pacing Electrophysiol J ; 19(2): 40-46, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30858056

RESUMO

BACKGROUND: The prognostic significance of paced QRS complex morphology on surface ECG remains unclear. This study aimed to assess long-term outcomes associated with variations in the paced QRS complex. METHODS: Adult patients who underwent dual-chamber pacemaker implantation with 20% or more ventricular pacing and a 12-lead ECG showing a paced complex were included. The paced QRS was analyzed in leads I and aVL. Long-term clinical and echocardiographic outcomes were compared at 5 years. RESULTS: The study included 844 patients (43.1% female; age 75.0 ±â€¯12.1). Patients with a longer paced QRS (pQRS) duration in lead I had a lower rate of atrial fibrillation (HR 0.80; p = 0.03) and higher rate of systolic dysfunction (HR 1.17; p < 0.001). Total pacing complex (TPC) duration was linked to higher rates of ICD implantation (HR 1.18; p = 0.04) and systolic dysfunction (HR 1.22, p < 0.001). Longer paced intrinsicoid deflection (pID) was associated with less atrial fibrillation (HR 0.75; p = 0.01), more systolic dysfunction (HR 1.17; p < 0.001), ICD implantation (HR 1.23; p = 0.04), and CRT upgrade (HR 1.23; p = 0.03). Exceeding thresholds for TPC, pQRS, and pID of 170, 146, and 112 ms in lead I, respectively, was associated with a substantial increase in systolic dysfunction over 5 years (p < 0.001). CONCLUSIONS: Longer durations of all tested parameters in lead I were associated with increased rates of left ventricular systolic dysfunction. ICD implantation and CRT upgrade were also linked to increased TPC and pID durations. Paradoxically, patients with longer pID and pQRS had less incident atrial fibrillation.

10.
Card Electrophysiol Clin ; 11(1): 141-146, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30717846

RESUMO

Cardiac resynchronization therapy has been proven to be clearly beneficial for patients with heart failure, a prolonged QRS duration, and a left ventricular ejection fraction ≤35%. Ejection fraction cutoff, however, is arbitrary and very likely excludes many patients who could benefit from cardiac resynchronization. This article describes the major detrimental effects of left bundle branch block and summarizes the data regarding the potential beneficial effects of cardiac resynchronization in patients with a left ventricular ejection fraction greater than 35%.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca Sistólica/terapia , Bloqueio de Ramo , Humanos , Estudos Prospectivos , Volume Sistólico
11.
Am J Cardiol ; 123(6): 967-971, 2019 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-30658920

RESUMO

Unicuspid aortic valve (UAV) is a rare malformation that is often difficult to distinguish from a bicuspid aortic valve (BAV) with commissural fusion by echocardiography or intraoperative surgical inspection. This study assessed the accuracy of intraoperative surgical inspection and two-dimensional echocardiography in diagnosing UAV compared to a gold standard of pathological diagnosis. The Mayo Clinic echocardiographic database, tissue registry database and electronic medical record were searched for all patients assigned a diagnosis of UAV by any technique. Transthoracic (TTE), transesophageal (TEE) echocardiographic, and surgical diagnoses were compared to pathological diagnosis as the standard. A clinical diagnosis of UAV was applied to 380 patients by 1 or more method and in 196 (52%) a pathologic evaluation was available to compare to the clinical description given by TTE, TEE, or surgical inspection. Of these 196 patients, only 58 (30%) had a pathological diagnosis of UAV; the majority were found to be BAVs by pathologic evaluation (n = 132, 67%). For diagnosing UAV, the sensitivity and specificity were 15% and 87% for TTE, 28%, and 82% for TEE, and 52% and 51% for surgical inspection, respectively. Valves with bicuspid morphology and extensive commissural fusion were frequently misclassified as UAV by all methods. In conclusion, intraoperative surgical inspection and echocardiography have limitations for diagnosing UAV due to difficulties in accurately assigning a correct morphological diagnosis, which suggests that the current understanding of the natural history of UAV may be inaccurate.


Assuntos
Valva Aórtica/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Transesofagiana/métodos , Doenças das Valvas Cardíacas/diagnóstico , Adulto , Valva Aórtica/anormalidades , Valva Aórtica/cirurgia , Feminino , Seguimentos , Doenças das Valvas Cardíacas/cirurgia , Humanos , Período Intraoperatório , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
Circ Arrhythm Electrophysiol ; 11(8): e006155, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30354311

RESUMO

Background The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressive increase in mortality was observed with aggregation of these noncardiac comorbidities. Conclusions The decision to replace the ICD should take into consideration not only left ventricular ejection fraction and history of ventricular arrhythmias, but also comorbid illnesses that may impact the duration and the quality of life.


Assuntos
Cardiomiopatias/terapia , Desfibriladores Implantáveis , Remoção de Dispositivo , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Boston , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Tomada de Decisão Clínica , Comorbidade , Bases de Dados Factuais , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/mortalidade , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Nível de Saúde , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Expectativa de Vida , Masculino , Pessoa de Meia-Idade , Minnesota , Seleção de Pacientes , Falha de Prótese , Qualidade de Vida , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
13.
JACC Clin Electrophysiol ; 4(10): 1362-1368, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30336883

RESUMO

OBJECTIVES: This study aimed to determine if epicardial cooling could repeatedly terminate induced atrial fibrillation (AF) in a canine heart. BACKGROUND: Rapid termination of AF could control symptoms and prevent atrial remodeling; however, defibrillation by internal electrical cardioversion is not tolerable to most patients. Cooling of the epicardium slows atrial conduction and may provide a less painful method to quickly terminate AF. METHODS: AF was induced with atrial myocardial epinephrine injections and rapid atrial pacing in an open-chest canine. Attempts at termination were performed with a small metal device that was either cooled to 5°C or kept at body temperature (control module). The device was placed on the epicardial surface in the oblique sinus. The time from device contact to termination of AF was recorded. RESULTS: In 5 different canine studies, there were 57 attempts at AF termination with either a 5°C module (34 attempts) or a control module (23 attempts). The median (interquartile range [IQR]) time to AF termination was 24 s (IQR: 15 to 35 s) for the 5°C therapy and 100 s (IQR: 47 to 240 s) for the body temperature treatments (p < 0.001). In the control group, there were 8 AF episodes that continued up to 4 min. Subsequent application of the 5°C cooling module terminated AF in all cases. CONCLUSIONS: Epicardial cooling in the oblique sinus is effective for repeated termination of AF in a canine heart. If reproduced in human studies, epicardial cooling with an implantable device may provide a method for management of patients with AF.


Assuntos
Fibrilação Atrial , Crioterapia/métodos , Cardioversão Elétrica/métodos , Animais , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Desfibriladores Implantáveis , Modelos Animais de Doenças , Cães , Pericárdio/fisiologia
14.
J Invasive Cardiol ; 30(9): E95-E96, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30158328

RESUMO

Coronary artery anomalies are relatively rare (approximately 1% on CTA). We present two exceedingly rare cases, as well as the first reported case of anomalous retro-aortic coronary arteries diagnosed with cardiac CTA and angiography.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico , Tomografia Computadorizada Multidetectores/métodos , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Raras
17.
J Am Heart Assoc ; 7(14)2018 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-29987121

RESUMO

BACKGROUND: Current thermal ablation methods for atrial fibrillation, including radiofrequency and cryoablation, have a suboptimal success rate. To avoid pulmonary vein (PV) stenosis, ablation is performed outside of the PV, despite the importance of triggers inside the vein. We previously reported on the acute effects of a novel direct current electroporation approach with a balloon catheter to create lesions inside the PVs in addition to the antrum. In this study, we aimed to determine whether the effects created by this nonthermal ablation method were associated with irreversible lesions and whether PV stenosis or other adverse effects occurred after a survival period. METHODS AND RESULTS: Initial and survival studies were performed in 5 canines. At the initial study, the balloon catheter was inflated to contact the antrum and interior of the PV. Direct current energy was delivered between 2 electrodes on the catheter in ECG-gated 100 µs pulses. A total of 10 PVs were treated demonstrating significant acute local electrogram diminution (mean amplitude decrease of 61.2±19.8%). After the survival period (mean 27 days), computed tomography imaging showed no PV stenosis. On histologic evaluation, transmural, although not circumferential, lesions were seen in each treated vein. No PV stenosis or esophageal injury was present. CONCLUSIONS: Irreversible, transmural lesions can be created inside the PV without evidence of stenosis after a 27-day survival period using this balloon-based direct current ablation approach. These early data show promise for an ablation approach that could directly treat PV triggers in addition to traditional PV antrum ablation.


Assuntos
Fibrilação Atrial/terapia , Eletroporação/métodos , Veias Pulmonares/diagnóstico por imagem , Animais , Fibrilação Atrial/fisiopatologia , Modelos Animais de Doenças , Cães , Eletrocardiografia , Estudos de Viabilidade , Seguimentos , Resultado do Tratamento
19.
J Cardiovasc Electrophysiol ; 28(8): 924-930, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28543771

RESUMO

INTRODUCTION: Cardiac pacing from the right ventricular apex is associated with detrimental long-term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long-term outcomes and lead-related complications associated with differing ventricular lead tip position. METHODS AND RESULTS: All adult patients who underwent dual-chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long-term outcomes and lead-related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005). CONCLUSIONS: Septal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Estimulação Cardíaca Artificial/tendências , Eletrodos Implantados/tendências , Septos Cardíacos/diagnóstico por imagem , Marca-Passo Artificial/tendências , Idoso , Fibrilação Atrial/etiologia , Estimulação Cardíaca Artificial/efeitos adversos , Doenças Cardiovasculares/diagnóstico por imagem , Doenças Cardiovasculares/terapia , Eletrodos Implantados/efeitos adversos , Feminino , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
20.
Europace ; 19(7): 1075-1083, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28340164

RESUMO

Denervation of the extrinsic cardiac sympathetic nervous system is a method of altering the autonomic tone experienced by the heart and vasculature. It has been studied and employed as a therapy for cardiac disease for decades. Currently, there is a high level of interest in using cardiac denervation for treatment of arrhythmias. This review describes the anatomy and physiology of the cardiac autonomic nervous system followed by a discussion of the mechanistic studies which provide a basis for the therapeutic use of sympathetic denervation. The clinical research supporting its use in human arrhythmias is then appraised, covering the standard indications, such as long QT syndrome, as well as future possibilities. Last, a detailed account of the methods for performing surgical cardiac denervation and percutaneous stellate ganglion anesthetic block is provided, including the complications of each procedure. An understanding of the anatomy and physiology of the cardiac autonomic nervous system along with the techniques of surgical denervation and percutaneous anesthetic block will allow the clinician to effectively discuss and implement these therapies.


Assuntos
Anestésicos Locais/administração & dosagem , Arritmias Cardíacas/cirurgia , Bloqueio Nervoso Autônomo/métodos , Frequência Cardíaca , Coração/inervação , Gânglio Estrelado/efeitos dos fármacos , Simpatectomia/métodos , Sistema Nervoso Simpático/cirurgia , Anestésicos Locais/efeitos adversos , Animais , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Bloqueio Nervoso Autônomo/efeitos adversos , Humanos , Injeções , Gânglio Estrelado/fisiopatologia , Simpatectomia/efeitos adversos , Sistema Nervoso Simpático/fisiopatologia , Resultado do Tratamento